一、产品概要及特征
旁(pang)(pang)路(lu)综合(he)作(zuo)用(yong)技术(shu)是(shi)一项提(ti)高(gao)配电(dian)(dian)(dian)网供电(dian)(dian)(dian)可(ke)靠性的(de)新型作(zuo)业技术(shu)。它包含(han)配网常规作(zuo)业,带电(dian)(dian)(dian)作(zuo)业,旁(pang)(pang)路(lu)作(zuo)业,移(yi)动电(dian)(dian)(dian)源作(zuo)业等多(duo)种作(zuo)业方式。YCE-LBS-12kV/24KV工程(cheng)型旁(pang)(pang)路(lu)负荷(he)开(kai)关(guan)(guan)是(shi)满足旁(pang)(pang)路(lu)综合(he)新型作(zuo)业技术(shu)的(de)核心(xin)设(she)备。此开(kai)关(guan)(guan)采用(yong)柔性电(dian)(dian)(dian)力电(dian)(dian)(dian)缆(lan),自(zi)锁定快(kuai)速插拔(ba)式电(dian)(dian)(dian)缆(lan)连接器,旁(pang)(pang)路(lu)开(kai)关(guan)(guan),移(yi)动箱变(bian)车等设(she)备以积木组合(he)方式搭建出不同的(de)配电(dian)(dian)(dian)单(dan)元相用(yong)户进(jin)(jin)行(xing)旁(pang)(pang)路(lu)供电(dian)(dian)(dian)。它不但可(ke)以使配电(dian)(dian)(dian)作(zuo)业人员在(zai)不间断(duan)供电(dian)(dian)(dian)状态(tai)下完成(cheng)线路(lu)检修工作(zuo),也能对较(jiao)难处(chu)理的(de)电(dian)(dian)(dian)缆(lan)线路(lu)的(de)故障抢(qiang)修进(jin)(jin)行(xing)临时(shi)供电(dian)(dian)(dian),缩小停(ting)(ting)电(dian)(dian)(dian)范围(wei),降低(di)停(ting)(ting)电(dian)(dian)(dian)对用(yong)户的(de)影响,提(ti)高(gao)了供电(dian)(dian)(dian)可(ke)靠性。旁(pang)(pang)路(lu)负荷(he)开(kai)关(guan)(guan)采用(yong)绝缘(yuan)及灭(mie)弧性能突出的(de)SF6气体(ti)及先进(jin)(jin)的(de)主(zhu)回路(lu)结构,开(kai)关(guan)(guan)特征如(ru)下:
1.1.本体(ti)内部注入的是绝缘及灭弧(hu)性(xing)能(neng)突出(chu)的高(gao)纯度(99.9%)SF6气体(ti),因此燃弧(hu)(Arc)开断时间短(duan)(1/2Cycle),绝缘恢(hui)复速度快,而且绝缘性(xing)能(neng)良(liang)好。
1.2.负荷电(dian)流分断时非(fei)常短(duan)的燃弧时间对开断部位触(chu)点的消耗很少,因此不需要维(wei)护或更换主回(hui)路。
1.3.主回路(lu)操作机构(gou)是简单倒三角型(xing)结(jie)构(gou)(Toggle),因此不受地震或(huo)大风带来的高(gao)频振动、重力、外部冲(chong)击(ji)等影(ying)响,性(xing)能非常稳定(ding),机械寿命(ming)长。
1.4本体(ti)采(cai)用的是经喷(pen)漆处理的SUS304不(bu)锈(xiu)钢材,因此不(bu)会被腐(fu)蚀(shi)。操作机构及机械传动部分也(ye)都(dou)安装在密封本体(ti)内部,因此不(bu)会因腐(fu)蚀(shi)而出现误动作。
1.5在大气(qi)压(ya)下(xia)(0㎏·f/C㎡)也**能(neng)(neng)够(gou)保证其(qi)绝缘(yuan)性(xing)(xing)能(neng)(neng)及开断性(xing)(xing)能(neng)(neng)。即本体内部的SF6气(qi)体即使泄露(lu),而其(qi)压(ya)力下(xia)降(jiang)为0时,也能(neng)(neng)保证全部绝缘(yuan)性(xing)(xing)能(neng)(neng)和开断性(xing)(xing)能(neng)(neng)。
1.6具有(you)带(dai)电显示(shi)、计数(shu)显示(shi);
1.7具备(bei)核相功能
二、电气性(xing)能参数
2.1产品采用标准(zhun)
IEC60502
GB3804
GB/T12706.4
GB/T8905
GB11023
DL/T844
2.2使用环境
①使用(yong)温度:-40~+85℃
②湿度条件:0~***(相对(dui)湿度)
③使(shi)用高度:海拨1000m以下
2.3额定参数
种(zhong) 类(lei) | 单 位 | 额 定 | ||||
型 号 | - | |||||
额定电压 | kV | 12 | 24 | |||
额定电流(liu) | A | 400 / 200 | ||||
额(e)定频率 | Hz | 50/60 | ||||
绝缘性能 | 额定(ding)冲击耐受电压 | 相对地 | kV | 75 | 125 | |
同(tong)相 端(duan)子间 | kV | 95 | 145 | |||
额(e)定(ding)工(gong)频耐受电(dian)压 | 相对地 | kV | 42 | 64 | ||
同相 端(duan)子间 | kV | 48 | 79 | |||
电(dian) 流(liu) 分合容(rong)量 | 负(fu)荷电流(liu) | A | 400 / 200 | |||
激磁电流 | A | 21 | ||||
电(dian)缆充电(dian)电(dian)流 | A | 25 | ||||
线路充电电流(liu) | A | 1.5 | ||||
额定短(duan)时耐受(shou)电流 | KA/4s | 20 | ||||
额(e)定关合闸电流(liu) | kA | 50 | ||||
气体压力(li) | 额定压力(li) | ㎏·f/㎠ | 0.5±0.1 | |||
防爆压力(li) | ㎏·f/㎠ | 4~6 | ||||
手动 合/分闸 功率 | ㎏ | 18±2 | ||||
重 量(liang) | 本 体 | ㎏ | 50 |
三(san)、旁路负荷(he)开关各部件介绍
项次 | 品 名 | 项次 | 品 名 |
1 | 计(ji) 数 器 | 8 | 上提把及吊耳 |
2 | 操作把手、铭(ming)牌 | 9 | 右侧铠装套管插座(zuo)及防(fang)尘盖 |
3 | 左侧铠(kai)装套管插座(zuo)及防(fang)尘盖 | 10 | 核相仪(yi)/控制(zhi)器(qi) |
4 | 手动闭(bi)锁装置(zhi) | 11 | 旁(pang)路开(kai)关固定(ding)器(qi) |
5 | SF6 气 压 表 | 12 | 接 地 孔 |
6 | SF6 气体注入阀 | 13 | 高压(ya)防爆(bao)装置 |
7 | 下 脚 架(jia) |
旁(pang)路(lu)负荷开(kai)关外形图(tu)
①套管(Bushing)
套(tao)管(guan)采用的是绝缘性能(neng)(neng)突(tu)出、而且适用于户(hu)外的环氧树脂。套(tao)管(guan)与本体间的缝隙是用密封性能(neng)(neng)良好的密封圈(O-Ring)来密封的。导电杆材(cai)料采用的是T2铜棒。
[进出线套管]
②防爆法兰(lan)(SafetyMembrane)
因开(kai)关本体内(nei)部出现异(yi)常,而(er)本体内(nei)部的(de)(de)气体压力(li)急剧(ju)上升(sheng)时,为了(le)防(fang)止外壳爆裂及内(nei)容(rong)物的(de)(de)飞(fei)散而(er)设置的(de)(de)安全装置。防(fang)爆法兰(lan)耐爆压力(li)为4~6㎏·f/C㎡。位置在(zai)操作者的(de)(de)反方向,从(cong)而(er)达到(dao)保(bao)护操作者的(de)(de)目的(de)(de)。
③气体注入口(GasFillingPort)
气(qi)体(ti)注入口,在正(zheng)常(chang)使(shi)用状态下请不要打(da)开注入口的盖子,否(fou)则本体(ti)内部气(qi)体(ti)就有可能泄(xie)露。即使(shi)内部气(qi)体(ti)压力下降(jiang),也可通(tong)过此(ci)注入口再充气(qi)。
④手(shou)动合闸(zha)/分闸(zha)手(shou)柄(ManualHandleforClose/Open)
以手动(dong)方(fang)式操作开关(guan)使用(yong)此手柄。
⑤手动闭锁装置(ManualLockingDevice)
以机械(xie)方式锁定开关(guan)本(ben)体(ti)时使(shi)用此装(zhuang)置,在合(he)闸或分闸状态下可锁定操作。
⑥吊(diao)钩(LiftingLugs)
吊(diao)运或安(an)装(zhuang)开关时请(qing)使用此吊(diao)钩。吊(diao)运或安(an)装(zhuang)时请(qing)不要(yao)使用其他部位,不然会损坏产(chan)品。
⑦本体支(zhi)撑(cheng)架(Leg)
放置到地面(mian)时为了不损伤(shang)开关本体的下部(bu)而设置的支撑用(yong)支架。
⑧接(jie)地(di)端子(GroundTerminal)
是连接(jie)(jie)(jie)开关(guan)本体与(yu)接(jie)(jie)(jie)地线的端(duan)(duan)子。不用其(qi)他附件就(jiu)可以直接(jie)(jie)(jie)向端(duan)(duan)子连接(jie)(jie)(jie)22~38mm2接(jie)(jie)(jie)地线。
⑨动(dong)作计数器(Counter)
表示本体的动(dong)作次(ci)数.
⑩压力(li)表(biao)(PressureGauge)
用于显示(shi)本(ben)体(ti)内部(bu)气体(ti)压力(li)(li)正常与否的(de)状态。压力(li)(li)表的(de)直径(jing)为76㎜,内部(bu)气体(ti)压力(li)(li)的(de)正常及异(yi)常范围(wei)用不同颜色做了(le)区分(fen)。
-正(zheng)常(chang)压力范围(绿色):0.1~0.5㎏·f/C㎡
-异常压力范围(红色):0.1㎏·f/C㎡以下
四、开关本体的操作
4.1防护等级
开关本体及机构箱的防(fang)护等级为IP67。
4.2绝缘和灭弧
绝缘和灭(mie)弧介质采(cai)用绝缘及灭(mie)弧性能良好(hao)的(de)高纯(chun)度的(de)(99.9%以(yi)上(shang))SF6气体(ti),具有*短的(de)灭(mie)弧时间(jian)(1/2周波)和良好(hao)的(de)绝缘恢复特(te)性。
使用压(ya)气式灭弧原理。负荷电(dian)(dian)流(liu)开断时,由于(yu)SF6气体(ti)(ti)的(de)电(dian)(dian)器特性(xing),电(dian)(dian)弧在SF6气体(ti)(ti)内(nei)冷却时直至(zhi)相当低(di)的(de)温度(du)时它仍导电(dian)(dian),电(dian)(dian)弧是(shi)在过(guo)(guo)零(ling)时开断,电(dian)(dian)流(liu)过(guo)(guo)零(ling)前的(de)截流(liu)小,由此避免(mian)了(le)高的(de)操作过(guo)(guo)电(dian)(dian)压(ya)。
4.3本体的操作
①手动(dong)合闸/分闸操作
以手(shou)动方(fang)式(shi)操(cao)作本体之前请先(xian)确认开关(guan)的当前合(he)闸(zha)(zha)/分(fen)闸(zha)(zha)状态。面对手(shou)动操(cao)作手(shou)柄,在分(fen)闸(zha)(zha)状态下正面的指示(shi)器指向分(fen)闸(zha)(zha)(右(you)侧),而红色(se)(se)合(he)闸(zha)(zha)环(huan)(huan)则(ze)处在右(you)上侧。此时(shi)如想合(he)闸(zha)(zha),只(zhi)需向下拉(la)右(you)上侧的合(he)闸(zha)(zha)环(huan)(huan)即可,此时(shi)正面的指示(shi)器则(ze)指向合(he)闸(zha)(zha)(左侧),而绿色(se)(se)分(fen)闸(zha)(zha)环(huan)(huan)则(ze)处在左上侧。
开关(guan)本体的(de)下部也有合闸/分(fen)(fen)闸状(zhuang)态(tai)指示(shi)器,此下部合/分(fen)(fen)闸指示(shi)器以机(ji)械方式连着开关(guan)内部的(de)主轴,因此可以准确地(di)了解到开关(guan)当前(qian)的(de)状(zhuang)态(tai)。
手动操(cao)作开关(guan)时(shi)所需力量为18±2㎏。手动操(cao)作机(ji)构为弹簧机(ji)构。
②手(shou)动(dong)闭(bi)锁/解锁操(cao)作
如需(xu)在合闸或分闸状态下以(yi)电动和机械方式闭锁(suo)(suo),只需(xu)把(ba)手(shou)动锁(suo)(suo)定拉(la)环向(xiang)下拉(la)即可。如需(xu)解锁(suo)(suo),只要把(ba)锁(suo)(suo)定拉(la)环向(xiang)上推即可。在手(shou)动闭锁(suo)(suo)状态下不能进(jin)行分/合闸操作。
4.4核相(xiang)控制器操作说明
●将(jiang)(jiang)开关和(he)控制器(qi)通过电缆正确连接(jie),将(jiang)(jiang)开关和(he)线路(lu)连接(jie)。
●打开核相控制器(qi)电(dian)源开关。按灯(deng)(deng)测试键,全部指(zhi)示(shi)灯(deng)(deng)应(ying)点(dian)亮,蜂鸣(ming)器(qi)鸣(ming)响,说明电(dian)池电(dian)压(ya)符(fu)合(he)要求(qiu),指(zhi)示(shi)灯(deng)(deng)和蜂鸣(ming)器(qi)正常(chang)。否则应(ying)更换指(zhi)示(shi)灯(deng)(deng)或(huo)蜂鸣(ming)器(qi),保持核相器(qi)处于正常(chang)可使用状(zhuang)态。
●**行三(san)个(ge)红灯(deng)是核(he)相(xiang)(xiang)错误(wu)指示。相(xiang)(xiang)位错误(wu)对应相(xiang)(xiang)指示灯(deng)点亮,同时蜂鸣器鸣响。
●第二行一个绿灯是(shi)核相正确指示(shi)。绿灯亮说明相位正确。
●第三(san)行是(shi)电(dian)源侧(ce)有电(dian)指(zhi)示,低(di)于(yu)额定电(dian)压20%灯(deng)不(bu)亮(liang)。灯(deng)亮(liang)表示对(dui)应(ying)的相(xiang)有电(dian)。第四行是(shi)负荷侧(ce)有电(dian)指(zhi)示,低(di)于(yu)额定电(dian)压20%灯(deng)不(bu)亮(liang)。灯(deng)亮(liang)表示对(dui)应(ying)的相(xiang)有电(dian)。
●当(dang)电源(yuan)侧和负荷侧6个(ge)(ge)绿色(se)指(zhi)示灯(deng)(deng)都点亮,并且三(san)个(ge)(ge)核相错(cuo)误(wu)红色(se)指(zhi)示灯(deng)(deng)全部不亮,绿色(se)核相正确指(zhi)示灯(deng)(deng)点亮,蜂鸣器不响才能合闸。
●本核(he)相器会(hui)用9V叠层电(dian)池作(zuo)为电(dian)源。电(dian)池电(dian)压低于7V时,右下角电(dian)池低红色指示灯(deng)会(hui)点亮,同时蜂鸣器鸣响,提示更(geng)换(huan)电(dian)池。更(geng)换(huan)电(dian)池后才(cai)能正(zheng)常(chang)核(he)相。
●任意一个核相(xiang)(xiang)错误指(zhi)(zhi)示(shi)(shi)灯(deng)(deng)亮(liang)都是(shi)核相(xiang)(xiang)错误,都不(bu)允许(xu)合(he)(he)闸。只有6个有电指(zhi)(zhi)示(shi)(shi)灯(deng)(deng)和(he)核相(xiang)(xiang)正确指(zhi)(zhi)示(shi)(shi)灯(deng)(deng)点亮(liang),相(xiang)(xiang)位错误指(zhi)(zhi)示(shi)(shi)灯(deng)(deng)都不(bu)亮(liang)才允许(xu)合(he)(he)闸。简单说就是(shi)红灯(deng)(deng)不(bu)亮(liang),7个绿灯(deng)(deng)亮(liang)允许(xu)合(he)(he)闸。
五、核相器面板
六、开关本(ben)体的安(an)装及保管
6.1产品保管方法(fa)
如果不急于安装产品,而(er)需(xu)要保管(guan)一段时间,请参考如下几点:
-*好不要解除包装,而保持出(chu)厂时的(de)原状态(tai)。
-尽量(liang)避免环境温度高(gao)或光线直射的(de)场所。
-尽量避免湿(shi)度非常高(gao)或地面上积水的场所(suo)。
6.2开关本体的安(an)装(zhuang)
6.2.1将(jiang)固(gu)定器(qi)安装在电线(xian)杆上;
6.2.2将旁(pang)路开关挂(gua)在固(gu)定器上;
6..2.3旁路开关(guan)安装(zhuang)金(jin)具
安装固定器
七、出现(xian)问(wen)题时(shi)的解决(jue)方法(fa)
7.1开(kai)关本体(ti)出现问题(ti)时
安装或(huo)使用过程中开关本体上出现问题时,请按如下方法检查并(bing)解决
序号项目原因分析方法分析结果解决方法
1气体压力下降到正常压力范围以下(*).经再充气后,在一段时间内维持正常压力气体自然泄露重新充气再充气后,压力重新下降开关本体有问题在现场无法解决问题,撤出开关内部压力增大,导致防爆法兰爆裂(**)在现场无(wu)法解决问题,撤出开关
2无法用手动合闸/分闸操作手柄操作手动闭锁装置为锁定状态手动锁(suo)定(ding)解(jie)除手动闭(bi)锁(suo)装置(zhi)手动闭(bi)锁(suo)装置(zhi)不(bu)在锁(suo)定(ding)状态位置(zhi)操(cao)作力(li)量不(bu)足加大(da)力(li)量,重新操(cao)作操(cao)作机构(gou)有问题现场无法解(jie)决问题
序(xu)号 | 项(xiang)目 | 原因分析方法 | 分析结果(guo) | 解决方法 |
1 | 气(qi)体(ti)压(ya)力下降到正(zheng)常压(ya)力范围以下(*). | 经 再充气(qi)后,在一段时间内维(wei)持正(zheng)常压力 | 气体(ti)自然泄露 | 重(zhong)新(xin)充(chong)气 |
再充气后,压力重(zhong)新(xin)下降 | 开(kai)关本体有(you)问题 | 在现场无法(fa)解(jie)决问题,撤出(chu)开关(guan) | ||
内部压(ya)力增(zeng)大,导致防爆(bao)法(fa)兰(lan)爆(bao)裂(**) | 在现场无法(fa)解决(jue)问题,撤出开(kai)关 | |||
2 | 无法用手动合闸/分(fen)闸操作(zuo)手柄操作(zuo) | 手动(dong)闭锁装置为锁定状态(tai) | 手动锁(suo)定 | 解(jie)除手动闭锁装置 |
手(shou)动闭锁(suo)装(zhuang)置(zhi)(zhi)不在锁(suo)定状态位置(zhi)(zhi) | 操(cao)作(zuo)力量不足 | 加大力(li)量,重新操(cao)作 | ||
操作机构有问题 | 现场无(wu)法解决(jue)问题(ti) |
(*)气体(ti)压力随环境(jing)温度的变化而变化,因此请参考『SF6气体(ti)压力–温度特性曲线(xian)』。
(**)防(fang)爆(bao)法兰爆(bao)裂(lie)时请参考『防(fang)爆(bao)法兰爆(bao)裂(lie)时的(de)措施(shi)』。
7.2防爆(bao)法兰(lan)爆(bao)裂(lie)时的措施
①防爆法兰的(de)爆裂说(shuo)明开关内部的(de)装置(zhi)已(yi)经(jing)受损,因此检查或(huo)撤出(chu)时一定要格外小心。
②防爆(bao)法兰爆(bao)裂(lie)的开关,无法维持正常(chang)绝缘及分合性能(neng),因此请(qing)及时撤(che)出并更换好的产品。
③这种开关(防爆法兰(lan)已爆裂(lie)的)在内部SF6绝缘气(qi)体燃(ran)弧(Arc)时分解出(chu)大量有(you)毒气(qi)体,因此在撤出(chu)时一定(ding)要(yao)小(xiao)心。
④防爆法(fa)兰爆裂时从本体内部流露出(chu)来(lai)的(de)有毒(du)气(qi)体将会污(wu)染开关表面(mian),因此相关人(ren)员检查或撤出(chu)时一定要(yao)穿上保护手套和(he)工作服,使(shi)污(wu)染物无(wu)法(fa)接(jie)触(chu)皮肤(fu)。
7.3发生现场(chang)无(wu)法解决(jue)的问题时